Use Of A Lowcost Cmos Detector And Crosspolarization Signal Isolation For
Oxygen Sensing
- doi: 10.1109/JSEN.2010.2089048
-
title: Use of a Low-Cost CMOS Detector and
Cross-Polarization Signal Isolation for Oxygen Sensing
- publisher: IEEE
- isbn:
- issn: 2379-9153
- rank: 3942
- access_type: LOCKED
- content_type: Journals
-
abstract: A portable, low-cost optical oxygen sensor
based on quenching of PtOEP emission is described. A CMOS image sensor
was used as detector, while cross-polarization was used for signal
isolation. At high oxygen concentrations, emission of PtOEP was quenched
leading to changes in the red channel of the CMOS sensor, while the
green and blue channels exhibited little signal change. Sensitivity of
the integrated sensor was comparable to that of commercial sensors
utilizing bulky and expensive external optical components. The wide
dynamic range of the demonstrated approach will permit use in a large
variety of point-of-care oxygen-sensing applications.
- article_number: 5605648
-
pdf_url:
https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5605648
-
html_url:
https://ieeexplore.ieee.org/document/5605648/
-
abstract_url:
https://ieeexplore.ieee.org/document/5605648/
- publication_title: IEEE Sensors Journal
- conference_location:
- conference_dates:
- publication_number: 7361
- is_number: 5752398
- publication_year: 2011
- publication_date: June 2011
- start_page: 1359
- end_page: 1360
- citing_paper_count: 14
- citing_patent_count: 1
- download_count: 459
- insert_date: 20101021
-
index_terms:
-
ieee_terms:
- CMOS integrated circuits
- Films
- Optical filters
- Optical sensors
- Optical imaging
- Optical polarization
- Detectors
-
author_terms:
- CMOS
- optical oxygen sensor
- polarization single isolation
-
dynamic_index_terms:
- Oxygen Sensor
- CMOS Detector
- Low-cost CMOS
- Oxygen Concentration
- Optical Sensors
- Blue Channel
- Low-cost Sensors
- Expensive Components
- Light Source
- Light-emitting Diodes
- LED Light
- Light Emission
- LEDs
- Emission Intensity
- Emission Factors
- Polarizability
- Excitation Light
- Sensor Applications
- Background Image
- Oxygen Electrode
- Clark Electrode
- Ethyl Cellulose
- Portable Sensor
- Glass Wafer
- Red, Green And Blue
-
authors:
-
Author Name: L. Shen
Affiliation: BioMicro Systems Laboratory, School of
Electronics and Computing, University of Cincinnati, Cincinnati, OH,
USA
Author URL:
https://ieeexplore.ieee.org/author/37589614100
ID: 37589614100
Order: 1
Author Affiliations:
-
BioMicro Systems Laboratory, School of Electronics and
Computing, University of Cincinnati, Cincinnati, OH, USA
-
Author Name: M. Ratterman
Affiliation: BioMicro Systems Laboratory, School of
Electronics and Computing, University of Cincinnati, Cincinnati, OH,
USA
Author URL:
https://ieeexplore.ieee.org/author/37592395000
ID: 37592395000
Order: 2
Author Affiliations:
-
BioMicro Systems Laboratory, School of Electronics and
Computing, University of Cincinnati, Cincinnati, OH, USA
-
Author Name: D. Klotzkin
Affiliation: Department of Electrical and Computer
Engineering, Binghamton University, Binghamton, USA
Author URL:
https://ieeexplore.ieee.org/author/37266261500
ID: 37266261500
Order: 3
Author Affiliations:
-
Department of Electrical and Computer Engineering, Binghamton
University, Binghamton, USA
-
Author Name: I. Papautsky
Affiliation: BioMicro Systems Laboratory, School of
Electronics and Computing, University of Cincinnati, Cincinnati, OH,
USA
Author URL:
https://ieeexplore.ieee.org/author/37296146000
ID: 37296146000
Order: 4
Author Affiliations:
-
BioMicro Systems Laboratory, School of Electronics and
Computing, University of Cincinnati, Cincinnati, OH, USA
Image Sensor
- sensor_type: CMOS
- resolution: 640x480
- dynamic_range: 28 dB
- pixel_size: 6 µm
- dark_current: Not specified
Optical Data
- focal_length: Not specified
- aperture: Not specified
- field_of_view: Not specified
- distortion: Not specified
Performance Metrics
Applications & Benefits
-
cell_imaging: Utilized successfully in
fluorescence-based cell imaging applications.
-
benefits: Low-cost, high sensitivity, and portable,
making it suitable for point-of-care oxygen sensing applications.
Supporting Organizations
-
supported_by: National Science Foundation under Grants
ECCS-0930305 and ECCS-0725812.
Manuscript Details
- publication_date: June 2011
Relevancy Score
- score: 9
-
missing_fields:
- focal length
- aperture
- field of view
- distortion
- frame rate
- signal to noise ratio
- sensitivity
- shutter speed
- power consumption
- noise
Processed JSON Filename
request_282003e8-159a-4ea7-b3d3-01b752db296b-use_of_a_lowcost_cmos_detector_and_crosspolarization_signal_isolation_for_oxygen_sensing.json