The Optofluidic Microscope A High Resolution Microscopeonachip System
- doi: 10.1109/CLEOPR.2007.4391165
-
title: The Optofluidic Microscope - A High Resolution
Microscope-on-A-Chip System
- publisher: IEEE
- isbn: 978-1-4244-1174-0
- issn:
- partnum: 07TH8953
- rank: 3777
- access_type: LOCKED
- content_type: Conferences
-
abstract: In this article, a complete on-chip high
resolution OFM device is presented. The OFM method abandons the
conventional microscope design and, instead, shares some similarities
with direct shadow imaging method where the target object is directly
placed on top of a CCD or CMOS imaging sensor chip. In direct shadow
imaging, the image resolution is no better than the sensor pixel size.
As the typical sensor pixel size is around 10 microns, direct shadow
imaging systems are unable to provide images that are comparable in
resolution to those of conventional microscopes.
- article_number: 4391165
-
pdf_url:
https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=4391165
-
html_url:
https://ieeexplore.ieee.org/document/4391165/
-
abstract_url:
https://ieeexplore.ieee.org/document/4391165/
-
publication_title: 2007 Conference on Lasers and
Electro-Optics - Pacific Rim
- conference_location: Seoul, Korea (South)
- conference_dates: 26-31 Aug. 2007
- publication_number: 4391083
- is_number: 4391084
- publication_year: 2007
- publication_date: 26-31 Aug. 2007
- start_page: 1
- end_page: 2
- citing_paper_count: 0
- citing_patent_count: 0
- download_count: 88
- insert_date: 20071204
-
index_terms:
-
ieee_terms:
- Optical imaging
- CMOS image sensors
- High-resolution imaging
- Sensor arrays
- Lab-on-a-chip
- Optical sensors
- Image resolution
- Pixel
- Optical microscopy
- Microfluidics
-
dynamic_index_terms:
- Line Scan
- Focused Ion Beam
- Conventional Microscopy
- Direct Imaging
- Use Of Microscopy
- Hole Array
- SU-8 Photoresist
- Hole Spacing
- Small Lenses
- Small Lens
-
isbn_formats:
-
format: CD,
value: 978-1-4244-1174-0,
isbnType: New-2005
-
format: Print ISBN,
value: 978-1-4244-1173-3,
isbnType: New-2005
-
authors:
-
Author Name: Xiquan Cui
Affiliation: Bioengineering and Electrical
Engineering, California Institute of Technology, Pasadena, CA,
USA
Author URL:
https://ieeexplore.ieee.org/author/37686761200
ID: 37686761200
Order: 1
Author Affiliations:
-
Bioengineering and Electrical Engineering, California Institute
of Technology, Pasadena, CA, USA
-
Author Name: Xin Heng
Affiliation: Bioengineering and Electrical
Engineering, California Institute of Technology, Pasadena, CA,
USA
Author URL:
https://ieeexplore.ieee.org/author/37548959600
ID: 37548959600
Order: 2
Author Affiliations:
-
Bioengineering and Electrical Engineering, California Institute
of Technology, Pasadena, CA, USA
-
Author Name: Lapman Lee
Affiliation: Bioengineering and Electrical
Engineering, California Institute of Technology, Pasadena, CA,
USA
Author URL:
https://ieeexplore.ieee.org/author/37955378100
ID: 37955378100
Order: 3
Author Affiliations:
-
Bioengineering and Electrical Engineering, California Institute
of Technology, Pasadena, CA, USA
-
Author Name: Changhuei Yang
Affiliation: Bioengineering and Electrical
Engineering, California Institute of Technology, Pasadena, CA,
USA
Author URL:
https://ieeexplore.ieee.org/author/37279098600
ID: 37279098600
Order: 4
Author Affiliations:
-
Bioengineering and Electrical Engineering, California Institute
of Technology, Pasadena, CA, USA
Image Sensor
- sensor_type: CMOS
- resolution: 640x480
- dynamic_range: Not specified
- pixel_size: 9.9 µm
- dark_current: Not specified
Optical Data
- focal_length: Not specified
- aperture: Not specified
- field_of_view: Not specified
- distortion: Not specified
Performance Metrics
Applications & Benefits
-
cell_imaging: The OFM system is currently being
evaluated for imaging blood cells and microorganisms.
-
benefits: Highly amenable to large-scale fabrication
and inclusion in a wider range of lab-on-a-chip systems.
Supporting Organizations
-
supported_by: California Institute of Technology,
Pasadena, CA, USA
Manuscript Details
- publication_date: 26-31 Aug. 2007
Relevancy Score
- score: 10
-
missing_fields:
- dynamic_range
- dark_current
- focal_length
- aperture
- field_of_view
- distortion
- signal_to_noise_ratio
- sensitivity
- shutter_speed
- power_consumption
- noise
Processed JSON Filename
request_6930f43b-3f27-4e6a-970b-7b69222e032c-the_optofluidic_microscope__a_high_resolution_microscopeonachip_system.json