Digital Holographic Interferometry For Particle Detector Diagnostic
- doi: 10.23919/MIPRO55190.2022.9803636
-
title: Digital holographic interferometry for particle
detector diagnostic
- publisher: IEEE
- isbn: 978-1-6654-8434-3
- issn: 1847-3938
- rank: 2294
- access_type: LOCKED
- content_type: Conferences
-
abstract: In high precision scattering experiments
particle tracks must often be reconstructed from a series of hits in
successive detector planes. The relative distance between these planes
is a critical parameter that must be monitored during operation. To
address this problem we have developed a digital holographic
interferometer dubbed Holographic Alignment Monitor (HAM) to be used in
the MUonE project at CERN. MUonE aims at a precision measurement of the
scattering angle between particles after an elastic muon-electron
scattering. The HAM is designed to monitor the relative distance between
position-sensitive sensor planes inside a MUonE tracking station with a
resolution better than the required 10 µm. The system uses a 532 nm
fiber-coupled laser source both to illuminate a portion of the detector
plane (object), and to provide the reference beam. A CMOS image sensor
acquires the raw data, and the reconstructed holographic image of the
silicon sensor being observed is computed using an algorithm containing
a Fourier transform. The relative distance between silicon planes is
monitored by superposing successive raw images of the same object on an
initial reference one and observing the interference fringes appearing
on the reconstructed holographic image. Preliminary tests have yielded a
distance resolution of less than 1 µm.
- article_number: 9803636
-
pdf_url:
https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9803636
-
html_url:
https://ieeexplore.ieee.org/document/9803636/
-
abstract_url:
https://ieeexplore.ieee.org/document/9803636/
-
publication_title: 2022 45th Jubilee International
Convention on Information, Communication and Electronic Technology
(MIPRO)
- conference_location: Opatija, Croatia
- conference_dates: 23-27 May 2022
- publication_number: 9803295
- is_number: 9803050
- publication_year: 2022
- publication_date: 23-27 May 2022
- start_page: 235
- end_page: 237
- citing_paper_count: 0
- citing_patent_count: 0
- download_count: 106
- insert_date: 20220627
-
index_terms:
-
ieee_terms:
- Optical fibers
- Optical interferometry
- Image resolution
- Scattering
- Detectors
- Holography
- Silicon
-
author_terms:
- digital holography
- interferometry
- detector diagnostic
- particle tracking
- calibration
- muon scattering
-
dynamic_index_terms:
- Holographic Interferometry
- Digital Holographic Interferometry
- Raw Images
- Image Sensor
- Camera Sensor
- Particle Tracking
- Fission Track
- Successive Images
- Interference Fringes
- Reference Beam
- Holographic Images
- Scattering Experiments
- Spread Experiments
- Spreading Experiments
- Sensor Plane
- Optical Fiber
- Fiber-optic
- Optical Fibre
- Time T1
- Time T0
- Hologram
- Raw Image Data
- Portion Of Surface
- Beam Source
- Tracking Detector
-
isbn_formats:
-
format: Print on Demand(PoD) ISBN,
value: 978-1-6654-8434-3,
isbnType: New-2005
-
format: CD,
value: 978-953-233-102-8,
isbnType: New-2005
-
format: Electronic ISBN,
value: 978-953-233-103-5,
isbnType: New-2005
-
authors:
-
Author Name: A. Arena
Affiliation: University of Rijeka, Rijeka,
Croatia
Author URL:
https://ieeexplore.ieee.org/author/37089434979
ID: 37089434979
Order: 1
Author Affiliations:
- University of Rijeka, Rijeka, Croatia
- INFN Sezione di Trieste, Trieste, Italy
-
Author Name: G. Cantatore
Affiliation: INFN Sezione di Trieste, University of
Trieste, Trieste, Italy
Author URL:
https://ieeexplore.ieee.org/author/37346854600
ID: 37346854600
Order: 2
Author Affiliations:
-
INFN Sezione di Trieste, University of Trieste, Trieste, Italy
-
Author Name: M. Karuza
Affiliation: University of Rijeka, Rijeka,
Croatia
Author URL:
https://ieeexplore.ieee.org/author/37086709147
ID: 37086709147
Order: 3
Author Affiliations:
- University of Rijeka, Rijeka, Croatia
- INFN Sezione di Trieste, Trieste, Italy
Image Sensor
- sensor_type: CMOS
- resolution: 4.92 megapixels
- dynamic_range: Not specified
- pixel_size: 2.2 µm
- dark_current: Not specified
Optical Data
- focal_length: Not specified
- aperture: Not specified
- field_of_view: Not specified
- distortion: Not specified
Performance Metrics
Applications & Benefits
- cell_imaging: Not specified
-
benefits: Used to monitor relative displacements at a
high precision for particle tracking.
Supporting Organizations
-
supported_by: University of Rijeka, University of
Trieste, INFN Sezione di Trieste
Manuscript Details
- publication_date: 23-27 May 2022
Relevancy Score
- score: 10
-
missing_fields:
- dynamic_range
- dark_current
- focal_length
- aperture
- field_of_view
- distortion
- frame_rate
- signal_to_noise_ratio
- sensitivity
- power_consumption
- noise
- cell_imaging
- benefits
Processed JSON Filename
request_07b18676-16ee-4f8a-b850-b6b4620d0d54-digital_holographic_interferometry_for_particle_detector_diagnostic.json