140 Framespersecond Ionoacoustic Imaging Detector For Realtime Particle
Therapy Monitoring
- doi: 10.1109/ICECS202256217.2022.9971077
-
title: 140 Frames-per-Second Ionoacoustic Imaging
Detector for Real-Time Particle Therapy Monitoring
- publisher: IEEE
- isbn: 978-1-6654-8824-2
- issn:
- rank: 22
- access_type: LOCKED
- content_type: Conferences
-
abstract: This work presents the development and
experimental validation of a ionacoustic detector that uses a
multi-channel sensor, a dedicated ASIC in 28nm CMOS and hardware DSP to
reduce the input-referred noise power by 1–2 orders of magnitude
compared to state of the art ionacoustic detectors. The most interesting
application of the ionacoustic technique is the real-time monitoring
with sub-millimeter precision of hadron therapy treatments, but the main
limitation of current detectors lies in their high latency and noise
power, not compatible with clinical treatments. The hereby presented
High-Resolution Proton Sound Detector exploits the parallel acquisition
and processing of 64 channels to obtain a 2D acoustic image of the
source with 256x256 pixel resolution, 140 fps and 70 mPaRMs
input-referred noise, resulting in 34 dB SNR with 0.8 Gy dose
deposition.
- article_number: 9971077
-
pdf_url:
https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9971077
-
html_url:
https://ieeexplore.ieee.org/document/9971077/
-
abstract_url:
https://ieeexplore.ieee.org/document/9971077/
-
publication_title: 2022 29th IEEE International
Conference on Electronics, Circuits and Systems (ICECS)
- conference_location: Glasgow, United Kingdom
- conference_dates: 24-26 Oct. 2022
- publication_number: 9970762
- is_number: 9970770
- publication_year: 2022
- publication_date: 24-26 Oct. 2022
- start_page: 1
- end_page: 4
- citing_paper_count: 0
- citing_patent_count: 0
- download_count: 81
- insert_date: 20221212
-
index_terms:
-
ieee_terms:
- Protons
- Medical treatment
- Imaging
- Detectors
- Real-time systems
- Radiation therapy
- Signal resolution
-
author_terms:
- Circuits and Systems for Biomedical Applications
- Analog Integrated Circuits
- Radiation Therapy
-
dynamic_index_terms:
- Particle Therapy
- Hadron Therapy
- Clinical Treatment
- Clinical Interventions
- Application Of Techniques
- Noise Power
- Source Images
- Acoustic Imaging
- Acoustic Tomography
- Dose Deposition
- Input-referred Noise
- State Of The Art
- State-of-the-art
- Frame Rate
- Single Channel
- Acoustic Waves
- Sound Waves
- Acoustic Signals
- Test Bench
- Proton Beam
- Clock Cycles
- Acoustic Sensors
- Pulsed Beam
- Acoustic Source
- Extra Dose
-
isbn_formats:
-
format: Print on Demand(PoD) ISBN,
value: 978-1-6654-8824-2,
isbnType: New-2005
-
format: Electronic ISBN,
value: 978-1-6654-8823-5,
isbnType: New-2005
-
authors:
-
Author Name: Elia A. Vallicelli
Affiliation: University of Milano - Bicocca,
Milano, Italy
Author URL:
https://ieeexplore.ieee.org/author/37086360840
ID: 37086360840
Order: 1
Author Affiliations:
- University of Milano - Bicocca, Milano, Italy
-
Author Name: Mattia Oliver Cosmi
Affiliation: University of Milano - Bicocca,
Milano, Italy
Author URL:
https://ieeexplore.ieee.org/author/37088573946
ID: 37088573946
Order: 2
Author Affiliations:
- University of Milano - Bicocca, Milano, Italy
-
Author Name: Mattia Tambaro
Affiliation: University of Padova, Padova, Italy
Author URL:
https://ieeexplore.ieee.org/author/37086935393
ID: 37086935393
Order: 3
Author Affiliations:
- University of Padova, Padova, Italy
-
Author Name: Andrea Baschirotto
Affiliation: University of Milano - Bicocca,
Milano, Italy
Author URL:
https://ieeexplore.ieee.org/author/37277065100
ID: 37277065100
Order: 4
Author Affiliations:
- University of Milano - Bicocca, Milano, Italy
-
Author Name: Marcello De Matteis
Affiliation: University of Milano - Bicocca,
Milano, Italy
Author URL:
https://ieeexplore.ieee.org/author/37400534900
ID: 37400534900
Order: 5
Author Affiliations:
- University of Milano - Bicocca, Milano, Italy
Image Sensor
- sensor_type: CMOS
- resolution: 256x256 pixels
- dynamic_range: 34 dB
- pixel_size: 0.35 mm (pitch)
- dark_current: Not specified in the document
Optical Data
- focal_length: Not specified in the document
- aperture: Not specified in the document
- field_of_view: Not specified in the document
- distortion: Not specified in the document
Performance Metrics
- frame_rate: 140 fps
- signal_to_noise_ratio: 34 dB
-
sensitivity: 10 μV/Pa, 590 mPa RMS (input-referred
noise)
- shutter_speed: Not specified in the document
- power_consumption: Not specified in the document
- noise: 70 mPa RMS (input-referred noise)
Applications & Benefits
- cell_imaging: Not specified in the document
-
benefits: Real-time monitoring of hadron therapy
treatments with sub-millimeter precision.
Supporting Organizations
-
supported_by: Italian Institute for Nuclear Physics
(INFN), Italian Ministry of University and Research (MUR)
Manuscript Details
- publication_date: 24-26 Oct. 2022
Relevancy Score
- score: 9
-
missing_fields:
- focal_length
- aperture
- field_of_view
- distortion
- shutter_speed
- power_consumption
- sensitivity
Processed JSON Filename
request_436375ab-284a-4fc3-a3b9-0aee9375b5b0-140_framespersecond_ionoacoustic_imaging_detector_for_realtime_particle_therapy_monitoring.json